Hager 3480 ARC Grade 1 Cylindrical Keyed Storeroom Set w/ Lever
What Environments Are Perfect for Heavy-Duty Cylindrical Locks?
Heavy-duty cylindrical locks are designed to withstand frequent use and demanding conditions. These robust locks are perfect for environments such as:
- Educational Institutions: Schools and universities need reliable locks to manage the constant flow of students and staff. Heavy-duty locks ensure security while standing up to everyday wear and tear.
- Healthcare Facilities: Hospitals and clinics require security solutions that are both durable and easy to use. These locks provide safety and reliability for areas with high traffic, safeguarding sensitive equipment and medications.
- Commercial Buildings: Office complexes and retail spaces benefit from heavy-duty locks to secure multiple entries and exits. Their resilience makes them ideal for protecting valuable assets and ensuring safety.
- Government Buildings: With a need for heightened security, government centers utilize these locks to secure restricted areas, private offices, and archives.
These diverse environments demand long-lasting, high-performance locking systems that can handle intense use without compromising security.
The lockset meets a range of certifications and compliance standards to ensure quality and safety. It is designed to be ADA compliant, adhering to the ANSI A 117.1 accessibility guidelines. This ensures it meets the necessary standards for accessibility for all users.
Additionally, the lockset is UL/cUL listed, capable of withstanding rigorous conditions, including up to 3 hours on A-label single doors. It also complies with the UL10C standard for positive pressure, which means it's tested to perform under significant pressure conditions.
For those concerned about quality and performance, the lockset carries a BHMA certification, following the ANSI A156.2, Series 4000, Grade 1 specifications, which confirm its durable build and dependable operation. It’s also ANSI A250.13 compliant, designed to withstand severe windstorm conditions.
Lastly, it is recognized with the Miami-Dade County, Florida NOA number 17-1226.23, indicating its tested endurance under extreme weather conditions common in that region.
Standard Faceplate Specifications for the Lockset
When purchasing a lockset, it's essential to know the default specifications of the included faceplate for compatibility and installation ease. The standard faceplate that accompanies the lockset measures 2-1/4 inches by 1-1/8 inches. It comes with a square corner design, ensuring a classic and clean look for your doors. These dimensions and style are typically provided as the default, so no special modifications are necessary for most installations.
All Locks and Latches include 4 7/8" ASA Strike - Only. 2 1/4" Full Lip Strikes and 2 3/4" T Strikes are available separately.
For detailed latchbolt specifications, each lockset comes with a 1/2 in. Stainless steel throw latchbolt. This ensures durability and a secure fit, making it a reliable choice for your security needs.
The combination of robust materials and versatile strike options provides adaptability to various installation requirements, ensuring both safety and convenience.
For those seeking additional information and detailed installation instructions, you can easily access the resources you need by clicking on the relevant document titles below. Each link will direct you to a comprehensive PDF guide, ensuring you have all the necessary information at your fingertips:
-
3400 Series Installation Instructions - I-LS00766.pdf
Get step-by-step guidance on installing the 3400 Series with this detailed manual. -
3400 Series Metal Door Template - T-LS00183-Rev03.pdf
Download this template for precise measurements and placement for metal doors. -
Conventional SFIC Lockset Timing Instruction - I-LS00310.pdf
Ensure perfect timing with your SFIC locksets by following these instructions. -
Hager 3400 Series Cut Sheet.pdf
Access specifications and dimensions for the 3400 Series with this cut sheet. -
LFIC Lockset Timing Instruction - I-LS01987.pdf
This guide provides timing instructions for LFIC locksets, ensuring optimal functionality. -
LFIC Tailpiece and Core Installation Instruction - I-LS01977-Rev1.pdf
Find detailed instructions for secure installation of LFIC tailpieces and cores. -
SFIC Lockset Timing Instruction - I-LS02384.pdf
Follow these instructions to time your SFIC locksets accurately and efficiently.
By clicking on each link, you can view or download the documents to ensure a successful installation process, providing you with all the support you need right at your fingertips.
Finish with BHMA code | 626 - US26D Satin Chrome or 613 - US10B Oil Rubbed Bronze or 605 - US3 Polish Brass or 606 - US4 Satin Brass or 625 - US26 Polish Chrome |
Cylinder Options | SCC - Schlage C Keyway or SFIC or LFIC |
Brand | Hager |
ANSI Cyl Lock Function | F86 - Storeroom |
Trim Design | ARC - Archer |
Series | Hager - 3400 Series |